Bahay> Mga Produkto> Pad na naka -mount na transpormer> 3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer
3000 kva three-phase pad mount transpormer

3000 kva three-phase pad mount transpormer

$8000-30000 /

Min. Order:1
Transportasyon:Ocean,Land,Air
Port:SHANGHAI
Mga katangian ng produkto

Model No.ZGS-H-3000

BrandYawei

Pagbalot at Paghahatid
Halimbawa ng Larawan :

The file is encrypted. Please fill in the following information to continue accessing it

2600kva-24.94kv-2
3000kva-24.94kv pad mount transpormer
Paglalarawan ng Produkto
Mga pagtutukoy ng produkto
Rating 3000 KVA
No. of Phases 3
Winding Configuration Delta – Wye / Wye – Wye/ Delta – Delta/ Wye – Delta
Vector Group As per requirement
Tapping Range ±2 x 2.5%/As per requirement
Winding Material Copper / Aluminum
Core Material Grain Oriented Silicon Steel Sheet
Impedance 3-5.75 %
Oil Temperature Rise 55 °C
Winding Temperature Rise 65 °C
Tap Changer Off-Load Tap Changer
IEEE Standards IEEE C57.12.00
Certification UL Listed
Efficiency DOE 2016

Ayon sa Standard :

1.Ansi/IEEE C57.12.00 Pamantayan sa IEEE para sa Pangkalahatang Mga Kinakailangan para sa Pamamahagi ng Liquid-Imersed, Power, at Regulate Tç

2.ansi/IEEE C57.12.90 IEEE Standard Test Code para sa Pamamahagi ng Liquid-Imersed, Power, at Regulate Transformers

2.iec 60076 Power Transformers

3.As NZS 60076 Power Transformers

4.CSA C227.4 Tatlong Phase Pad na naka -mount na mga transformer ng pamamahagi

6.Gost r 52719 Power t ransformers likidong pamamahagi, kapangyarihan, at pag-regulate ng mga transformer-pangkalahatang mga pagtutukoy

Ang mga nakagawiang pagsubok ng transpormer ay kasama ang:

1. Winding Resistance Test ng Transformer

2.Transformer ratio test

3.Transformer vector group test

4.Measurement ng impedance boltahe/maikling circuit impedance (punong tap) at pagkawala ng pag -load (maikling circuit test)

5.Measurement ng pagkawala ng walang pag-load at kasalukuyang (bukas na circuit test)

6.Measurement ng paglaban sa pagkakabukod

7.Dielectric Mga Pagsubok ng Transformer.

8.Tests sa on-load tap-changer.

9.Oil Pressure Test sa Transformer Upang Suriin Laban sa Mga Leakage Nakaraan

Ang pinaka -mapagkumpitensyang mga produktong yawei:

Pad Mounted Transformer, Power Transformer, Distribution Transformer, Pole Mounted Transformer

Kung mayroon kang anumang mga katanungan, mangyaring makipag -ugnay sa akin kaagad.

Bahay> Mga Produkto> Pad na naka -mount na transpormer> 3000 kva three-phase pad mount transpormer
Magpadala ng Inquiry
*
*

Makikipag -ugnay kami sa iyo kaagad

Punan ang karagdagang impormasyon upang makapag -ugnay sa iyo nang mas mabilis

Pahayag ng Pagkapribado: Napakahalaga sa amin ng iyong privacy. Nangako ang aming kumpanya na huwag ibunyag ang iyong personal na impormasyon sa anumang paglawak sa iyong tahasang mga pahintulot.

Ipadala